Floline
Corporation promoted by a young entrepreneur over a decade
ago is a trusted name in Valves. We are serving the process
industries in the country with a wide range of quality
assurance and services as the prime basis for attaining
highest quality levels, Apart from stringent in house stage
inspection by qualified Engineers.
A wide range of standard valves are offered from ex-stock to
meet urgent requirements.
GENERAL TECHNICAL INFORMATION ON VALVES
Excellent work & proven design features are the very
basis of the valves.standard
valves are with cast end pieces, bodies & bonnets.
However on request valves are manufactured from rolled or
forged bar stock materials as well.
CAST VALVES
Casting material conforms to relevant ASTM material
specification. Casting are of highest quality, well
proportioned and defect free with heat mark. Wall thickness
are
of very liberal nature confirming to ANSI B 16:34 Material
Test and heat treatment certificated are furnished to the
client.
BAR STOCK VALVES
On request high pressure valve or tailor made valves are
machined from Carbon Steel, Stainless Steel higher, Alloy
materials bar stocks.
MATERIAL OF CONSTRUCTION
Cast, Carbon Steel, Stainless Steel & Cast Alloy,
Nickel, Monel, Hastalloy B & C or any
other material as per the clients request.
END CONNECTIONS
Any of the following end connections are provided as may be
suitable for
the clients requirement.
| Flanged
end |
-
|
to
ANSI B 16.5 RF with serrated finish |
| |
-
|
to
DIN standard 2532, 2533 |
| |
-
|
to
British standard BS.10 Table D,E,F |
| Butt-weld
ends |
-
|
to
ANSI B 16.25, B 16.9 |
| Socket
weld ends |
-
|
to
ANSI B 16.11 |
| Screwed
ends |
- |
to
ANSI B 16.11 BSP, BSPT or NPT |
| Face
to Face dimensions to ANSI B 16.10, BS 2080 |
RATINGS
ASA 150 # 300 # 600 # 800 # 900 # 1500 #
DIN PN 10,16,25,40,64,100
SIZE RANGE
Flanged end : 15 mm to 700 mm
Screwed end : 6 mm to 50 mm
Welded end : 6 mm to 50 mm
INSPECTION
We manufactured under any third party inspection or clients
own inspection
to their satisfaction.
TESTING
Each valve is hydrostatically tested as per ANSI B 16, 34,
BS, DIN or Equivalvent codes as per the ratings, Pneumatic
test is also offered.
SUGGESTING
While installing valve on a dirty contaminated systems
install a strainer on upstream
side to minimize maintenance.
|